(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
The electrical CPX terminal is a modular peripheral system for valveterminals. The system is specifically designed so that the valve terminal can be adapted to suit different applications. The modular system design lets you configure the number of valves, inputs and additional outputs to suit the application.
CPX-FB36
CPX-FB13
CPX-M-FB34
Type | CPX-FB36 | ||
---|---|---|---|
Fieldbus interface | 2x M12x1 socket, D-coded, 4-pin | ||
Baud rates [Mbit/s] | 10/100 | ||
Protocol | EtherNet/IP | ||
Modbus TCP | |||
Max. address capacity, inputs [byte] | 64 | ||
Max. address capacity, outputs[byte] | 64 | ||
LED displays (bus-specific) | MS NS TP1 TP2 | = Module status = Network status = Network active port 1 = Network active port 2 | |
Device-specific diagnostics | Module and channel-oriented diagnostics Module undervoltage Diagnostic memory | ||
Configuration support | EDS file L5K export with CPX-FMT | ||
Parameterisation | Diagnostic behaviour Fail-safe response Forcing of channels Idle mode characteristics Signal setup System parameters | ||
Additional functions | EtherNet/IP Quickconnect Ring topology (DLR) Acyclic data access via "Explicit Message" and Ethernet Integrated switch IP addressing via DHCP, DIL switch or operator unit Channel-oriented diagnostics via fieldbus Start-up parameterisation in plain text via fieldbus System status can be represented using process data Additional diagnostic interface for operator units | ||
Control elements | DIL switches | ||
Operating voltage | Nominal value [V DC] | 24 | |
Permissible range [V DC] | 18 to 30 | ||
Current consumption (at nominal voltage) [mA] | Typically 100 | ||
Protection class to EN 60529 | IP65, IP67 | ||
Temperature range | Operation [℃] | -5 to +50 | |
Storage/transport [℃] | -20 to +70 | ||
Materials | PA reinforced | ||
Note on materials | RoHS-compliant | ||
Grid dimension [mm] | 50 | ||
Dimensions (incl. interlinking block) W x L x H [mm] | 50 x 107 x 50 | ||
Product weight [g] | 125 |
Type | CPX-FB13 | |
---|---|---|
Fieldbus interface | Sub-D socket, 9-pin (EN 50 170) Galvanically isolated 5 V | |
Baud rate [Mbit/s] | 0.0096 to 12 | |
Addressing range | 1 to 125 Set using DIL switch | |
Product range | 4: Valves | |
Ident. number | 0x059E | |
Communication types | DPV0: Synchronous communication DPV1: Asynchronous communication | |
Configuration support | GSD file and bitmaps | |
Max. address capacity | Inputs [byte] | 64 |
Outputs [byte] | 64 | |
LED displays (bus-specific) | BF: Bus fault | |
Device-specific diagnostics | Identifier and channel-oriented diagnostics EN 50170 (PROFIBUS standard) | |
Parameterisation | Start-up parameterisation via configuration interface in plain text (GSD) Asynchronous parameterisation via DPV1 | |
Additional functions | Storage of the last 40 errors with timestamp (access via DPV1) 8-bit system status in image table for inputs 2-byte inputs and 2-byte outputs, system diagnostics in image table | |
Control elements | DIL switch | |
Operating voltage | Nominal value [V DC] | 24 |
Permissible range [V DC] | 18 to 30 | |
Power failure buffering [ms] | 10 | |
Current consumption | Typically 200 | |
Protection class to EN 60529 | IP65, IP67 | |
Temperature range | Operation | -5 to +50 |
Storage/transport | -20 to +70 | |
Materials | PA-reinforced PC | |
Grid dimension | 50 | |
Dimensions (incl. interlinking block) W x L x H | 50 x 107 x 50 | |
Weight | 115 |
Type | CPX-M-FB34 | ||
---|---|---|---|
Fieldbus interface | 2x RJ45 push-pull socket, AIDA | ||
Baud rate [Mbit/s] | 100 | ||
Protocol | PROFINET RT | ||
PROFINET IRT | |||
Max. address capacity | Inputs [byte] | 64 | |
Outputs [byte] | 64 | ||
LED displays | (bus-specific) | M/P NF TP1 TP2 | = Maintenance/PROFIenergy = Network fault = Network active port 1 = Network active port 2 |
(product-specific) | M PL PS SF | = Modify, parameterisation = Load supply = Electronic supply, sensor supply = System fault | |
Device-specific diagnostics | Channel and module-oriented diagnostics Undervoltage of modules Diagnostic memory | ||
Configuration support | GSDML file | ||
Parameterisation | System parameters Diagnostic behaviour Signal setup Fail-safe response Forcing of channels | ||
Additional functions | Start-up parameterisation in plain text via fieldbus Fast startup (FSU) Channel-oriented diagnostics via fieldbus Asynchronous data access via fieldbus and via Ethernet System status can be represented using process data Additional diagnostic interface for operator units | ||
Control elements | DIL switch, optional memory card | ||
Operating voltage | Nominal value [V DC] | 24 | |
Permissible range [V DC] | 18 to 30 | ||
Intrinsic current consumption at nominal operating voltage [mA] | Typically 120 | ||
Protection class to EN 60529 | IP65, IP67 | ||
Temperature range | Operation [℃] | - 5 to +50 | |
Storage/transport [℃] | -20 to +70 | ||
Material of housing | Die-cast aluminium | ||
Grid dimension [mm] | 50 | ||
Dimensions (incl. interlinking block) W x L x H [mm] | 50 x 107 x 80 | ||
Weight [g] | 280 |
Part Number |
---|
CPX-FB13 |
CPX-FB36 |
CPX-M-FB34 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | RoHS | Housing material | Intrinsic current consumptiont nominal operating voltage | IP rating | Protocol | Configuration support | Baud rate | Corrosion resistance class (CRC) | Manufacturer part # | Weight (g) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
11,437,524 VND | 1 Piece(s) | 15 Day(s) | 10 | PA-reinforced, PC | Typ. 200 mA | IP65, IP67 | Profibus DP | GSD file | 96 ... 12000 kbit/s | 1 - Low corrosion stress | 195740 | 115 | ||
18,167,436 VND | 1 Piece(s) | 41 Day(s) | - | PA-reinforced | Typ. 100 mA | IP67, IP65 | EtherNet/IP, Modbus® TCP | EDS file, L5K export with CPX-FMT | 10/100 Mbit/s | 1 - Low corrosion stress | 1912451 | 125 | ||
20,537,874 VND | 1 Piece(s) | 41 Day(s) | - | Die-cast aluminum | Typ. 120 mA | IP67, IP65 | PROFINET IRT, PROFINET RT | GSDML file | 100 Mbit/s | 0 - No corrosion stress | 548751 | 280 |
Loading...Tải…
Nominal DC operating voltage(V) | 24 | DC operating voltage range(V) | 18-30 | Min. Ambient temperature(°C) | -5 |
---|---|---|---|---|---|
Max. Ambient temperature(°C) | 50 | Min. Storage temperature(°C) | -20 | Max. Storage temperature(°C) | 70 |
Max. address capacity inputs | 64 byte | Max. address capacity outputs | 64 byte |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy