(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
[Specifications]
- CTEU fieldbus modules for valve terminals
- Festo-specific interface (I-Port) - Input modules CTSL for detecting sensor signals
- Connection for the installation system CPI from Festo
- Direct and easy networking of valve terminals and other devices via a bus connection
- Wide range of applications thanks to high degree of protection to IP65/67
- Universal connection technology (Sub-D, M12, terminal strip)
- Optional decentralised installation of bus node for connecting two valve terminals
- Basic diagnostics: undervoltage, short circuit
The bus node CTEU-EP is a module within the CTEU series which can be used to connect I-Port devices with specification V1.0 to an EtherNet/IP or Modbus/TCP bus. Depending on the installation, the bus node provides two I-Port interfaces for the connection of I-Port devices.
Fieldbus interface | ||
---|---|---|
Protocol | EtherNet/IP | |
Power is supplied to the bus node and the connected I-Port devices by means of an M12 plug, 5-pin, A-coded, on the top side of the housing. | ||
Transmission rate [Mbps] | 110/100 | |
Fieldbus interface | 2x socket, M12x1, 4-pin, D-coded | |
Internal cycle time | 1 ms per 1 byte of user data | |
Inputs/outputs | ||
Max. address volume for inputs [byte] | 64 | |
Max. address volume for outputs [byte] | 64 | |
Nominal operating voltage [V DC] | 24 | |
Operating voltage range [V DC] | 18 to 30 | |
Intrinsic current consumption at nominal operating voltage [mA] | Typically 65 | |
Max. power supply [A] | 4 | |
Device-specific diagnostics | System diagnostics | |
Undervoltage | ||
Communication error | ||
Parameterisation | Diagnostic behaviour | |
Fail-safe and idle response | ||
Additional functions | AddressConflictDetection (ACD) | |
Acyclic data access via "Explicit Message" | ||
EtherNet/IP Quickconnect | ||
IP addressing via DHCP, DIL switch, fieldbus or FFT | ||
Integrated switch | ||
Ring topology (DLR) | ||
SNMP | ||
Start-up parameterisation in plain text via fieldbus | ||
System status can be displayed using process data | ||
Web servers | ||
Configuration support | EDS files | |
Control elements | DIL switch | |
LED display | Product-specific | PS: Operating voltage for electronics and load supply |
X1: System status of module at I-Port 1 | ||
X2: System status of module at I-Port 2 | ||
Fieldbus-specific | TP1: Network active port 1 | |
TP2: Network active port 2 | ||
NS: Network status |
Part Number |
---|
CTEU-EP |
CTEU-PN |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | RoHS | Intrinsic current consumptiont nominal operating voltage | Protocol | Configuration support | Baud rate | Fieldbus interface, protocol | Fieldbus interface, type | Fieldbus interface, transmission rate | Fieldbus interface, number of poles/wires | Manufacturer part # | Weight (g) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
13,744,235 VND | 1 Piece(s) | 15 Day(s) | 10 | Typ. 65 mA | EtherNet/IP, Modbus® TCP | EDS file | 10/100 Mbit/s | - | - | - | - | 2798071 | 98 | ||
13,881,539 VND | 1 Piece(s) | 41 Day(s) | 10 | Typ. 80 mA | PROFINET | GSDML file | - | PROFINET RT | Ethernet | 100 Mbit/s | 4 | 2201471 | 93 |
Loading...Tải…
Housing material | PA | Max. power supply(A) | 4 | Nominal DC operating voltage(V) | 24 |
---|---|---|---|---|---|
DC operating voltage range(V) | 18-30 | IP rating | IP65, IP67 | Min. Ambient temperature(°C) | -5 |
Max. Ambient temperature(°C) | 50 | Min. Storage temperature(°C) | -20 | Max. Storage temperature(°C) | 70 |
Max. address capacity inputs | 64 byte | Max. address capacity outputs | 64 byte | Internal cycle time | 1 ms per 1 byte of user data |
Corrosion resistance class (CRC) | 2 - Moderate corrosion stress |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy