(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
SSCNET III compatible positioning block FX3U-20SSC-H.
[Features]
・ By supporting SSCNET III, positioning control with excellent cost performance, high speed, high accuracy, and excellent noise resistance has been realized
・ Various functions that are easier to use, such as labor-saving wiring using optical fiber cables and real-time monitoring of servo information can support various positioning controls
・ It supports high resolution encoders of MR-J3 and MR-J4 servo motors, and pulse rate setting of 262,144 PLS/rev is possible
・ It is effective for high accuracy control and low speed stability
・ High-speed serial communication with high synchronization of SSCNET III has realized highly accurate control between 2 axes
・ You can make parameter setting and table operation setting easily by using the setting software
・ Long distance connection is possible up to 50 m between servo stations
・ The table operation function contributes to significant reduction in program development labor-hours
・ Speed change and target position change are possible during positioning
・ Override function (It can change the operating speed easily to the specified rate)
・ Various origin return modes (DOG type / data set type / stopper type)
・ 1 PLS command function enables fine inching
・ It has a constant change function of torque limit value
・ Manual pulsar input up to 100 kHz
The SSCNET III-compatible block allows to easily build a high-speed, high-precision positioning system in combination with MR-J3/MR-J4 Servo Motors.
Up to 2 servo amplifiers can be connected using optical fiber cables.
The setup software makes parameter setting and table operation setup easy.
FX3U-20SSC-H
FX2NC-100MPCB Model Power Cable included.
Can be mounted on a 35-mm wide DIN rail.
Number of Control Axis | 2 axes (independent/simultaneous) | |
---|---|---|
Interpolation Function | 2-axis linear interpolation, circular interpolation | |
Pulse Output System | SSCNETIII | |
Maximum Frequency | 50 MHz | |
Acceleration/Deceleration Processing | Automatic trapezoidal acceleration/deceleration, approximate sigmoid acceleration/deceleration | |
Single Control Unit | Pulse, μm, 10-4 inch, mdeg | |
Positioning Range | -2,147,483,648 to +2,147,483,647 pulses -2,147,483,648 to +2,147,483,647 [× (position data multiplier) μm] -2,147,483,648 to +2,147,483,647 [× (position data multiplier) ×10-4 inches] -2,147,483,648 to +2,147,483,647 [× (position data multiplier) mdeg] The position data multiplier can be set to ×1, ×10, ×102or ×103using a parameter. A desired value can be set in a range of -2,147,483,648 to +2,147,483,647 in equivalent pulses. | |
Programming Language | Sequence program (BFM can be specified directly using an operand of a FROM/TO command or other applied command.) The table operation setup data (table information) can be set by FX Configurator-FP model setting / monitoring tool. | |
Position Data | 1 point (set by the sequence program) If table operation is performed, 300 points can be set for each of the X-axis, Y-axis and XY-axis (in a table). | |
Manual Pulsar Connection | Connectable (Differential line driver) | |
Absolute Position Detection (ABS Current Position Read) | Set by parameters | |
Number of Occupied Input/Output | 8 sequencer input/output points are occupied (can be counted either on the input side or output side) | |
Applicable Sequencer | FX3U, FX3UC "Connecting to a connector-type sequencer" Connecting to an FX3UC requires an FX2NC-CNV-IF or FX3UC-1PS-5V. | |
Weight | 0.3 kg | |
Power Supply Specifications | ||
Power Supply Voltage | 5 V DC, 100 mA (internal power supply from sequencer) 24 V DC +20% -15%, ripple (p-p) within 5% (external power supply) | |
Allowable Momentary Power Outage Duration | Operation will continue following a momentary power failure of 5 ms or less | |
Power Consumption | 5 W (220 mA / 24 V DC) | |
Power Supply Fuse | 1 A | |
Input Specifications | ||
Control Input | Control input: 2 points per axis (DOG, START) Interrupt input: 2 points per axis (INT0, INT1) Manual pulsar input: 1 point per axis (øA, øB) | |
Input Signal Voltage | DOG, START, INT0, INT1 | 24 V DC +20% -15% |
øA, øB | 3 V DC to 5.25 V DC | |
Input Signal Format | DOG, START, INT0, INT1 | Dry contact input For sink input: NPN open collector transistor For source input: PNP open collector transistor |
øA, øB | Differential line driver (AM26LS31 or equivalent) | |
Input Signal Current | DOG, START, INT0, INT1 | 7.0 mA ±1 mA |
øA, øB | 3.0 mA to 8.5 mA | |
Input ON Sensitivity | DOG, START, INT0, INT1 | 4.5 mA or more |
øA, øB | 3.0 mA or more | |
Input OFF Sensitivity | DOG, START, INT0, INT1 | 1.5 mA or less |
øA, øB | 0.5 mA or less | |
Input Loading Speed | DOG, START, INT0, INT1 | Hardware filter 1 ms or less |
øA, øB | 2-phase pulse 100 kHz or less (duty 50%) | |
Circuit Insulation | Opto-isolator insulation | |
Operation Display | The LED lights up when the input is ON |
Ambient Temperature | 0 to 55°C: When operating, -25 to 75°C: When saving | ||
---|---|---|---|
Relative Humidity | 5 to 95% RH (no condensation): when operating | ||
Vibration Resistance | When Mounting to DIN Rail | Frequency: 10 to 57 Hz | Single amplitude: 0.035 mm, 10 times in each direction of X, Y and Z (total of 80 minutes each) |
Frequency: 57 to 150 Hz | Acceleration: 4.9 m/s2 10 times in each direction of X, Y and Z (total of 80 minutes each) | ||
When Mounting Directly | Frequency: 10 to 57 Hz | Single amplitude: 0.075 mm, 10 times in each direction of X, Y and Z (total of 80 minutes each) | |
Frequency: 57 to 150 Hz | Acceleration: 9.8 m/s2 10 times in each direction of X, Y and Z (total of 80 minutes each) | ||
Impact Resistant | 147 m/s2, for a duration of 11 ms, 3 times in each direction of X, Y and Z with a half-sine pulse | ||
Noise Resistance | Achieved through a noise simulator with a noise voltage of 1,000 Vp-p, noise width of 1 μs, the rise time of 1 ns and frequency of 30 to 100 Hz | ||
Dielectric Strength | Between all terminals and earth terminal: 500 V AC for 1 minute | ||
Insulation Resistance | Between all terminals and earth terminal: 5 MΩ or more at 500 V DC on an ohmmeter | ||
Operating Atmosphere | There shall be no corrosive gas or flammable gas and not much conductive dust | ||
Altitude of Use | 2,000 m or lower Cannot be used in environments pressurized above atmospheric pressure. Doing so may cause failure. |
Part Number |
---|
FX3U-20SSC-H |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng |
---|---|---|---|---|
8,257,500 VND | 1 Piece(s) | Quote |
Loading...Tải…
Number of Control Axis | (Independent/Simultaneous) 2 shafts | Representative Standard | CE / UL | Applicable sequencer | FX3U / FX3UC |
---|---|---|---|---|---|
Single Control Unit | pulse, μm, 10^-4 inch, mdeg | Number of Control Axis(Axis) | (Independent/Simultaneous) 2 shafts | Pulse Output System | SSCNETIII |
Please check the type/dimensions/specifications of the part FX3U-20SSC-H in the MELSEC-F Series Positioning Contro (SSCNET) series.Vui lòng kiểm tra kiểu/kích thước/thông số kỹ thuật của phần FX3U-20SSC-H trong chuỗi MELSEC-F Series Positioning Contro (SSCNET).
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy